• Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
• Temperature setting:
   ON 35 °C - OFF 65 °C (operating temperature of
   heating system itself)
   Anti-freeze: ON < 10 °C - OFF 40 °C 
• 2 Connecting alternatives (optional)
   Connecting leads (AL) 0.8 m, 3 x 0.75 mm² PVC
   –> Other lengths upon request
   Lead out terminal (DK) 0.08 - 2.5 mm²
• Mounting position: horizontal
• Fastening
   Snap fitting for 35 mm DIN rail 
   –> Special versions upon request



Order Data

Voltage Power rating Weight Order No. DK Order No. AL
115 V AC 130W 1400 gr. 115130LDK0 115130LAL0
230 VAC 130W 1400 gr. 230130LDK0 230130LAL0
400 V AC 130W 1400 gr. 400130LDK0 400130LAL0
440 V AC 130W 1400 gr. 440130LDK0 440130LAL0
115 V AC 220 W 1400 gr. 115220LDK0 115220LAL0
230 VAC 220 W 1400 gr. 230220LDK0 230220LAL0
400 V AC 220 W 1400 gr. 400220LDK0 400220LAL0
440 V AC 220 W 1400 gr. 440220LDK0 440220LAL0
115 V AC 300 W 1400 gr. 115300LDK0 115300LAL0
230 VAC 300 W 1400 gr. 230300LDK0 230300LAL0
400 V AC 300 W 1400 gr. 400300LDK0 400300LAL0
440 V AC 300 W 1400 gr. 440300LDK0 440300LAL0
115 V AC 400 W 1400 gr. 115400LDK0 115400LAL0
230 VAC 400 W 1400 gr. 230400LDK0 230400LAL0
400 V AC 400 W 1400 gr. 400400LDK0 400400LAL0
440 V AC 400 W 1400 gr. 440400LDK0 440400LAL0
115 V AC 500 W 1400 gr. 115500LDK0 115500LAL0
230 VAC 500 W 1400 gr. 230500LDK0 230500LAL0
400 V AC 500 W 1400 gr. 400500LDK0 400500LAL0
440 V AC 500 W 1400 gr. 440500LDK0 440500LAL0


Dimensional drawing LH3002
Wiring diagramm
Dimensioned drawing

Details

- Slight surface temperature by the use of an integrated thermostat

- No additional thermostat necessary

- Tamper-proof

- Special temperature settings selectable

 

 

 