Product group P1

Control cabinet heatings, Thermostat controlled heaters, Lm-therm GmbH, super-maxi DK
Lead out terminal (DK)
Control cabinet heatings, Thermostat controlled heaters, Lm-therm GmbH, super-maxi AL
Connecting leads (AL)

Technical details

• Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
• Temperature setting:
   ON 35 °C - OFF 65 °C (operating temperature of
   heating system itself)
   Anti-freeze: ON < 10°C - OFF 40°C
• 2 Connecting alternatives (optional)
   Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
   –> Other lengths upon request
   Lead out terminal (DK) 0.08 - 2.5 mm²
• Mounting position: vertical
• Fastening
   Holder
   –> Special versions upon request



Order data

Voltage Power rating Weight Order-No. DK Order-No. AL
115 V AC 250 W 1400 g 115250DK0 115250AL0
230 V AC 250 W 1400 g 230250DK0 230250AL0
400 V AC 250 W 1400 g 400250DK0 400250AL0
440 V AC 250 W 1400 g 440250DK0 440250AL0
115 V AC 500 W 1400 g 115500DK0 115500AL0
230 VAC 500 W 1400 g 230500DK0 230500AL0
400 V AC 500 W 1400 g 400500DK0 400500AL0
440 V AC 500 W 1400 g 440500DK0 440500AL0


Dimensional drawing super-maxi